Crypto Mining Containers

MinerPark industrial crypto mining container
Overview: Units and features (basic set)
  • Body: Standard shipping container
  • Integrated Plug&Play principle
  • Operating conditions: -45°C to +35°C
  • Mining equipment racks
  • Standalone hot/cold corridor zones
Air conditioning and cooling system
  • The forced air system consists of industrial fans of 800 mm in diameter, a capacity of 22,000 m3/hour, and power of 0.75 kW. The system capacity allows for the entire air renewal in 30 seconds. The fans are equipped with gravity grilles to protect the system from precipitation and act as a check valve. Optionally, the fans can be controlled by a PVC (frequency converter), which helps to control the rotation speed automatically.
  • Reusable inlet air filtration system class G3, protective visors above the inflow window.
Power distribution system
  • The wiring diagram is divided into several non-volatile areas. Each area is equipped with an input switchgear that has an 800-amp input circuit breaker adjusted for loads of up to 430 kW. Circuit breakers protecting ASIC miners (25 amps per device) are integrated into the switchgear. Each 25-amp circuit breaker is connected to a cable that powers the ASIC miner. Depending on the type of ASIC miner, it can be powered by two 3x1.5 mm2 cables with C13 connectors or a single 3x2.5 mm2 cable with a C19 connector. Each switchgear has a power metering device. The power supply circuit complies with the wiring regulations; it uses copper conductors only. All system units are grounded.
  • LED lighting and additional sockets
Local network
  • Local Cat 5e Internet network, 24-port switchers
Installable equipment options:
  • Heat recovery ventilation system for cold climate;
  • Security and fire alarm system;
  • Video surveillance and monitoring system;
  • Fire extinguishing system;
  • Access control system;
  • Automated air conditioning monitoring system;
  • Paint color of your choice, print shop;
  • Equipment units Sever, including heat recovery units with thermal sensors and PVC, fan covers, forced air heater use options, extra filters, extended covers;
  • Adiabatic cooling system
  • Dielectric rubber floor covering for cold corridors;
  • Fanless design option to lower the costs.
MinerPark МР360
MinerPark МР360
Load capacity: 360 ASIC miners
Power: up to 3.5 kW each (Antminer S19; Whatsminer; Avalon etc.)
Total power: 1.3 MW
Body: 40HQ standard shipping container
MinerPark МР480
MinerPark МР480
Load capacity: 480 ASIC miners
Power: up to 3.5 kW each (Antminer S19; Whatsminer; Avalon etc.)
Total power: 1.8 MW
Body: 45HQ standard shipping container
Модель МР175
MinerPark МР175
Load capacity: 175 ASIC miners
Power: up to 3.5 kW each (Antminer S19; Whatsminer; Avalon etc.)
Total power: 620 kW
Body: 20HQ standard shipping container
Модель МР90
MinerPark МР90
Load capacity: 90 ASIC miners
Power: up to 3.5 kW each (Antminer S19; Whatsminer; Avalon etc.)
Total power: 320 kW
Body: 10HQ standard shipping container